Answer Question
0
0

For an in screed cable, fitted to insulation, a minimum 70mm screed is required. This level can be reduced to 50mm depending on the type of screed used, for example liquid screed may allow for less.
For an in screed cable, fitted onto an insulated concrete floor, a minimum of 35mm is required.

Marked as spam
Posted by Klima Technical (Questions: 36, Answers: 53)
Asked on 21st March 2019 11:10 am
98 views
Add comment
0
Private answer

For an in screed cable, fitted to insulation, a minimum 70mm screed is required. This level can be reduced to 50mm depending on the type of screed used, for example liquid screed may allow for less.
For an in screed cable, fitted onto an insulated concrete floor, a minimum of 35mm is required.

Marked as spam
Posted by Klima Technical (Questions: 36, Answers: 53)
Answered on 21st March 2019 12:39 pm
Add comment

Post your Answer

Attach YouTube/Vimeo clip putting the URL in brackets: [https://youtu.be/Zkdf3kaso]